DLO 2KV Torsion Resistant Cable to UL 44
Application
These cables are used for main power layout from the nacelle to the base of the wind tower.
Standards
UL 44
ICEA S-68-516/NEMA WC-8
Construction
Conductor:Stranded tinned copper according to ASTM B-172/ ASTM B-33.
Insulation: Special EPR. XLPO can be offered upon request.
Sheath: Special CPE. XLPO can be offered upon request.
Technical Data
Rated Voltage U0/U (Um):2000V
Operating Temperatures:-40℃~+90℃
Minimum Bending Radius:fixed: 4×OD; flexing: 6×OD
Torsion Application:+/-180°/m
Flame Retardant:IEEE
Oil Resistant:Yes
UV Resistant:Yes
Cold Resistant:CSA C 22.2
Dimensions and Weight
Construction | Nominal Overall Diameter | Nominal Weight |
---|---|---|
No. of cores×AWG/MCM | mm | kg/km |
1×14 | 5.9 | 37 |
1×12 | 6.3 | 69 |
1×10 | 7.2 | 100 |
1×8 | 8.2 | 142 |
1×6 | 10.1 | 200 |
1×4 | 11.5 | 286 |
1×2 | 12.6 | 370 |
1×1 | 16.1 | 637 |
1×1/0 | 17.5 | 715 |
1×2/0 | 18.5 | 830 |
1×3/0 | 20.2 | 1104 |
1×4/0 | 21.7 | 1298 |
1×262 | 24.8 | 1590 |
1×313 | 26.4 | 1872 |
1×373 | 28.2 | 2176 |
1×444 | 30.0 | 2570 |
1×535 | 32.2 | 3046 |
1×646 | 34.8 | 3600 |
1×777 | 37.0 | 4290 |
1×929 | 39.5 | 5144 |
1×1111 | 44.4 | 6070 |